Furnace blinking red light? Decode the error code by brand

Pick the brand on your furnace’s label, tell us what kind of light or display the control board has, and tap what you see. You get what the manufacturer says it means, what you can safely check yourself, and what the fix usually costs.

Short answer

A blinking light on the furnace control board is a fault code: count the flashes between pauses and match them with the chart inside the furnace door. On most boards a steady light means power and no fault. The most common faults are an open limit (often a dirty filter), a pressure switch or vent problem, and an ignition lockout.

CODE DECODER
1 · Brand on the furnace label

Also Bryant and Payne (Carrier brands)

2 · What does the control board have?
3 · What do you see?

Smell gas or a CO alarm is sounding? Ignore the code. Leave the house now without switching anything on or off, and call your gas utility or 911 from outside.

What the code means
—

Choose a brand, a board type and what you see.

How to read your furnace’s blinking light

Read the code before you turn anything off. Removing power or the blower door can erase the code on some boards, and the door switch cuts power to the control.

  1. Remove only the outer (burner) door if needed and look through the small window in the blower door, or at the board itself.
  2. Watch at least two full cycles. Count the flashes between the long pauses. On Carrier boards, count the short flashes, then the long ones.
  3. Note the color (red, green, amber) and whether it is steady, slow or rapid.
  4. Compare with the chart printed on the inside of the furnace door or the wiring diagram. If it differs from this page, trust the label: it belongs to your board.
  5. Reset the power once at most. Carrier and Lennox lockouts clear themselves after 1–3 hours; resetting again and again only hides the fault.

What 1 to 9 flashes mean on each brand

The same number of flashes means different things on different brands. Three flashes is a pressure switch problem on Goodman and Lennox, a draft pressure error on Trane, and an open limit on Rheem. Carrier uses two-digit codes instead.

FlashesGoodmanSingle blinking LEDTraneRed LED flash codesLennoxSingle blinking LEDRheemGreen status + amber flame LEDs
1System lockout: ignition retries or recycles exceeded.—Flame present with the gas valve de-energized.Soft lockout.
2Pressure switch stuck closed.System lockout: ignition retries or recycles exceeded.Pressure switch closed while the combustion air inducer is off.Pressure switch circuit open.
3Pressure switch stuck open.Draft pressure error: a venting, pressure switch or inducer problem.Pressure switch open while the combustion air inducer runs.Limit circuit open.
4Open high limit: the furnace is overheating.Open temperature limit switch: the furnace is overheating.Primary limit switch open: overheating.Pressure switch circuit closed (when it should be open).
5Flame sensed without the gas valve energized.Flame sensed when no flame should be present.Rollout switch open.Twinning fault (only on twinned furnaces).
6Open rollout switch: flame rolled out of the burner area.115 V polarity reversed, igniter (triac) fault, poor grounding or low system voltage.Pressure switch cycle lockout.—
7Low flame signal.Gas valve circuit error.Lockout: burners failed to light.—
8—Low flame sense.Lockout: burners lost flame too many times.—
9—Open inducer limit switch.Line voltage polarity incorrect.—
From the manufacturer documents listed with each brand’s chart below. A dash means the board does not use that count.

Carrier furnace error codes

Also Bryant and Payne (Carrier brands). Codes change between control boards, so confirm yours against the chart printed inside the furnace door. Decode it step by step →

Status LED: 2-digit code

Carrier gas furnaces with an amber or red status LED seen through the sight glass in the blower door (documented for the 58SB0A/58SB1A). Boards with a digital display show the same first two digits, followed by a decimal, for example 33.1. Count the short flashes (first digit), then the long flashes (second digit): 3 short + 3 long = code 33.

CodeWhat it means · what to doMost likely part
13 · 1 short + 3 longLimit circuit lockout: a limit, draft safeguard, flame rollout or blocked-vent switch stayed open more than 3 minutes. Auto-resets after 3 hours.
Replace a dirty air filter and open any closed supply or return vents. If the code returns, a technician must find why the furnace overheats.
High-limit switch$100–$375
14 · 1 short + 4 longIgnition lockout: the furnace failed to light and prove flame in 4 tries. Auto-resets after 3 hours.
Make sure the gas supply to the furnace is on (other gas appliances work). If it is, the usual causes are a dirty flame sensor, a failed igniter or the gas valve.
Flame sensor$80–$250
21 · 2 short + 1 longGas heating lockout: the control does not auto-reset.
Turn the power off, wait 5 minutes and retry once. If it returns: a stuck gas valve relay on the control or a miswired gas valve. This needs a technician.
Furnace control board$300–$650
22 · 2 short + 2 longAbnormal flame-proving signal: flame is sensed while the gas valve should be closed. The inducer keeps running.
Likely a stuck-open or leaking gas valve. This needs a technician.
Gas valve$200–$800
23 · 2 short + 3 longPressure switch did not open.
Obstructed pressure tubing or a pressure switch stuck closed. This needs a technician.
Visit $75–$200
24 · 2 short + 4 longThe 3-amp low-voltage (24 V) fuse on the control is blown.
A short in the 24 V wiring, including the thermostat wires. The fuse must be replaced with a 3-amp fuse only. This needs a technician.
Visit $75–$200
31 · 3 short + 1 longPressure switch did not close or reopened. After 5 minutes open, the inducer shuts off for 15 minutes and retries.
Outside, check that the furnace vent pipe is not blocked by snow, ice, leaves or a nest. Other causes: excessive wind, a disconnected pressure tube, a weak inducer motor or a failed pressure switch.
Draft inducer motor$400–$1,100
33 · 3 short + 3 longLimit circuit fault: a limit, draft safeguard, flame rollout or blocked-vent switch is open. If it stays open over 3 minutes, it becomes code 13.
Replace a dirty air filter and open any closed supply or return vents. Other causes: a loose blower wheel, a failed blower motor or capacitor, or a restricted vent. A tripped rollout switch needs a manual reset by a technician.
High-limit switch$100–$375
34 · 3 short + 4 longIgnition proving failure: no flame sensed during ignition. The control retries 3 more times, then locks out (code 14).
Check that the gas supply is on. Then the usual causes are a dirty flame sensor (Carrier lists 4.0–6.0 microamps as nominal), the igniter or the gas valve.
Flame sensor$80–$250
45 · 4 short + 5 longControl circuitry lockout: flame circuit failure, stuck gas valve relay or software error. Auto-resets after 1 hour.
Reset the power once. If the code repeats, Carrier says to replace the control board.
Furnace control board$300–$650
OffOff: no 115 V power to the control.
Check the furnace breaker and the service switch near the furnace, and that the blower door is fully closed (its switch cuts power).
Visit $75–$200
Rapid flashingRapid flashing: 115 V line polarity is reversed. The furnace will not run.
The hot and neutral wires are swapped. This needs a technician.
Visit $75–$200
11 · 1 short + 1 longNo previous code stored. Codes clear after 72 hours.
Run a heating cycle to see whether a new code appears.
—
12 · 1 short + 2 longBlower on after power-up. Normal: the blower runs 90 seconds if power returns during a call for heat.
Nothing to fix.
—
Steady onSteady on: the control has 24 V power. No fault.
Nothing to fix.
—
Source: Carrier — 58SB0A/58SB1A Installation, Start-up, Operating and Service Instructions (Fig. 44 service label, Fig. 51)

Goodman furnace error codes

Also Amana and Daikin (same manufacturer). Codes change between control boards, so confirm yours against the chart printed inside the furnace door. Decode it step by step →

Single blinking LED

Goodman 80% furnaces with one diagnostic LED on the control board (documented for the GMS8). The chart is also printed on the wiring diagram inside the furnace. Count the flashes between pauses.

CodeWhat it means · what to doMost likely part
1 flashSystem lockout: ignition retries or recycles exceeded.
Check that the gas supply is on, then reset the power once. If it locks out again, the flame sensor, igniter or gas valve are the usual suspects.
Flame sensor$80–$250
2 flashesPressure switch stuck closed.
This needs a technician.
Visit $75–$200
3 flashesPressure switch stuck open.
Outside, check that the furnace vent pipe is not blocked by snow, ice, leaves or a nest. Otherwise: a blocked or disconnected pressure hose, a weak inducer motor or a failed switch.
Draft inducer motor$400–$1,100
4 flashesOpen high limit: the furnace is overheating.
Replace a dirty air filter and open any closed supply or return vents. If it continues, the blower or the limit switch needs a technician.
High-limit switch$100–$375
5 flashesFlame sensed without the gas valve energized.
A lingering flame or a slow-closing gas valve. This needs a technician.
Gas valve$200–$800
6 flashesOpen rollout switch: flame rolled out of the burner area.
The rollout switch is a manual-reset safety device: a technician must find why it tripped. On some models this code also means an open control fuse.
Visit $75–$200
7 flashesLow flame signal.
Often a coated or oxidized flame sensor that needs cleaning.
Flame sensor$80–$250
OffOff: control failure.
First check the furnace breaker, the service switch and that the blower door is closed. With power present and the LED still off, the control board is suspect.
Furnace control board$300–$650
Rapid flashingRapid flashes: 115 V polarity reversed. Verify the ground.
This needs a technician.
Visit $75–$200
Steady onSteady on: normal operation.
Nothing to fix.
—
Source: Goodman — GMS8 Technical Manual RT6621031r2 (Nov 2013), control LED codes

3-character display

Newer Goodman, Amana and Daikin 80% single-stage furnaces with a 3-character display and three buttons (documented for the GR9S80, AR9S80, GD9S80 and AD9S80, 2023). Read the code on the display. Stored faults: press left or right until L6F shows, then press the center button.

CodeWhat it means · what to doMost likely part
EE0Lockout after 3 ignition retries: no flame, or flame lost after lighting.
Check that the gas supply is on. Outside, check that the furnace vent pipe is not blocked by snow, ice, leaves or a nest. Then: igniter, flame sensor or inducer.
Flame sensor$80–$250
EE1Pressure switch closed at the start of the heating cycle.
Sticking switch contacts or a short in the switch wiring. This needs a technician.
Visit $75–$200
EE2Pressure switch not closed: the inducer runs but the furnace does not light.
Outside, check that the furnace vent pipe is not blocked by snow, ice, leaves or a nest. Otherwise: a pinched or blocked pressure hose, a weak inducer or a faulty switch.
Draft inducer motor$400–$1,100
EE3Primary limit open: not enough air over the heat exchanger. The blower runs, no heat.
Replace a dirty air filter and open any closed supply or return vents. Then: blower speed or a failed blower motor.
High-limit switch$100–$375
EE4Flame sensed with no call for heat.
A short in the flame-sense circuit, a lingering flame or a slow-closing gas valve. This needs a technician.
Gas valve$200–$800
EE5Open fuse: short in the low-voltage wiring.
Find and fix the short, then replace the fuse. This needs a technician.
Visit $75–$200
EE6Weak flame signal. The furnace still runs.
Clean or reposition the flame sensor; check gas pressure.
Flame sensor$80–$250
EELIgniter circuit problem: wiring, a shorted igniter or a poor ground.
This needs a technician.
Hot surface ignitor$100–$250
EEAIgniter relay fault, reversed 115 V polarity or poor ground.
This needs a technician.
Furnace control board$300–$650
EEbGas valve not energized when it should be.
Gas valve wiring, or the control board. This needs a technician.
Furnace control board$300–$650
EECGas valve energized when it should not be.
Gas valve wiring, or the control board. This needs a technician.
Furnace control board$300–$650
E10Grounding fault or poor neutral connection.
This needs a technician.
Visit $75–$200
E11Open rollout switch.
Gas pressure, burner alignment or a restricted burner. This needs a technician.
Visit $75–$200
EEnIgniter open (broken or disconnected).
Check the igniter wiring; replace a damaged igniter.
Hot surface ignitor$100–$250
EEJInducer relay error.
Goodman says to replace the control board.
Furnace control board$300–$650
EEEInternal control board fault.
Goodman says to replace the control board.
Furnace control board$300–$650
EbLHard lockout: the blower motor draws very little current.
Loose motor wiring or a burnt blower motor. This needs a technician.
Blower motor replacement (indoor)$500–$2,300
EbUHard lockout: the blower motor draws too much current.
Loose wiring, or line wires reversed at the control. This needs a technician.
Blower motor replacement (indoor)$500–$2,300
EALThe R-32 sensor detected a refrigerant leak. Heating stops and only the fan runs.
Normal operation resumes once no leak is detected and a 5-minute delay has passed. Have the indoor coil checked for a leak.
Refrigerant leak repair$200–$1,500
EAFLost communication with the R-32 sensor. Only the fan runs.
Loose or damaged sensor wire, or no R-32 cooling unit paired. This needs a technician.
Visit $75–$200
EASR-32 sensor fault. Only the fan runs.
Replace the R-32 sensor. This needs a technician.
Visit $75–$200
EArA2L relay fault on the control board. Only the fan runs.
Cycle the power once; if it repeats, the board is replaced.
Furnace control board$300–$650
idLIdle: normal operation.
Nothing to fix.
—
Source: Goodman / Daikin — Service and Troubleshooting, 80% Single Stage Gas Furnaces RS6621301 (Nov 2023)

Trane furnace error codes

Also American Standard (same manufacturer). Codes change between control boards, so confirm yours against the chart printed inside the furnace door. Decode it step by step →

Red LED flash codes

Trane and American Standard furnaces with a red "error" LED on the integrated furnace control (documented for the *UX2/*DX2 two-stage furnaces). Count the red flashes between pauses. On power-up, the control replays its last 4 faults, newest first.

CodeWhat it means · what to doMost likely part
2 flashesSystem lockout: ignition retries or recycles exceeded.
Check that the gas supply is on and reset the power once. If it locks out again: flame sensor, igniter or gas valve.
Flame sensor$80–$250
3 flashesDraft pressure error: a venting, pressure switch or inducer problem.
Outside, check that the furnace vent pipe is not blocked by snow, ice, leaves or a nest.
Draft inducer motor$400–$1,100
4 flashesOpen temperature limit switch: the furnace is overheating.
Replace a dirty air filter and open any closed supply or return vents.
High-limit switch$100–$375
5 flashesFlame sensed when no flame should be present.
This needs a technician.
Gas valve$200–$800
6 flashes115 V polarity reversed, igniter (triac) fault, poor grounding or low system voltage.
This needs a technician.
Hot surface ignitor$100–$250
7 flashesGas valve circuit error.
This needs a technician.
Gas valve$200–$800
8 flashesLow flame sense.
A dirty flame sensor is a common cause.
Flame sensor$80–$250
9 flashesOpen inducer limit switch.
This needs a technician.
Draft inducer motor$400–$1,100
10 flashesInducer communication error.
This needs a technician.
Draft inducer motor$400–$1,100
Solid redSolid red: internal gas valve error or low thermostat (24 V) voltage.
This needs a technician.
Furnace control board$300–$650
Solid red + greenSolid red with solid green: continuous reset from a blown fuse or an internal error.
This needs a technician.
Furnace control board$300–$650
Source: Trane — Installer’s Guide 18-CD25D1-6, *UX2/*DX2 furnaces (IFC red LED flash codes)

Lennox furnace error codes

Lennox gas furnaces. Codes change between control boards, so confirm yours against the chart printed inside the furnace door. Decode it step by step →

Single blinking LED

Lennox furnaces whose integrated control has one LED and a push button for code recall (documented for the ML195UH, 2019). Count the flashes. Press the button under 5 seconds to replay the last 5 faults, newest first.

CodeWhat it means · what to doMost likely part
1 flashFlame present with the gas valve de-energized.
This needs a technician.
Gas valve$200–$800
2 flashesPressure switch closed while the combustion air inducer is off.
This needs a technician.
Visit $75–$200
3 flashesPressure switch open while the combustion air inducer runs.
Outside, check that the furnace vent pipe is not blocked by snow, ice, leaves or a nest.
Draft inducer motor$400–$1,100
4 flashesPrimary limit switch open: overheating.
Replace a dirty air filter and open any closed supply or return vents.
High-limit switch$100–$375
5 flashesRollout switch open.
This needs a technician.
Visit $75–$200
6 flashesPressure switch cycle lockout.
Outside, check that the furnace vent pipe is not blocked by snow, ice, leaves or a nest.
Draft inducer motor$400–$1,100
7 flashesLockout: burners failed to light.
Check that the gas supply is on. Then: igniter, flame sensor or gas valve.
Hot surface ignitor$100–$250
8 flashesLockout: burners lost flame too many times.
A dirty flame sensor is a common cause. This needs a technician.
Flame sensor$80–$250
9 flashesLine voltage polarity incorrect.
This needs a technician.
Visit $75–$200
OffLED off: no power to the control, or a control hardware fault.
Check the furnace breaker, the service switch and that the blower door is closed.
Furnace control board$300–$650
Steady onLED on: normal operation.
Nothing to fix.
—
Source: Lennox — ML195UH Installation Instructions 507268-03 (02/2019)

Display with E-codes

Newer Lennox furnaces whose control shows E-codes such as E250 (documented for the ML180UHVK, 2025). Read the code on the display. E000 means no error in memory.

CodeWhat it means · what to doMost likely part
E110Line voltage low. Waits for recovery.
This needs a technician.
Visit $75–$200
E111Line voltage polarity reversed.
This needs a technician.
Visit $75–$200
E113Line voltage high.
This needs a technician.
Visit $75–$200
E117Poor ground detected.
This needs a technician.
Visit $75–$200
E125Control hardware failure. 5-minute lockout.
This needs a technician.
Furnace control board$300–$650
E200Hard lockout: rollout switch open or previously opened.
This needs a technician.
Visit $75–$200
E204Gas valve relay problem.
This needs a technician.
Furnace control board$300–$650
E223Low pressure switch failed to close (stuck open).
Outside, check that the furnace vent pipe is not blocked by snow, ice, leaves or a nest.
Draft inducer motor$400–$1,100
E224Low pressure switch failed to open (stuck closed).
This needs a technician.
Visit $75–$200
E227Low pressure switch opened during the run or the ignition trial.
Outside, check that the furnace vent pipe is not blocked by snow, ice, leaves or a nest.
Draft inducer motor$400–$1,100
E240Low flame current in heating mode.
A dirty flame sensor is a common cause.
Flame sensor$80–$250
E241Flame sensed out of sequence and still present.
This needs a technician.
Gas valve$200–$800
E250Primary limit switch opened: overheating.
Replace a dirty air filter and open any closed supply or return vents.
High-limit switch$100–$375
E27060-minute soft lockout: flame failure on ignition after the maximum retries.
Check that the gas supply is on. Then: igniter, flame sensor or gas valve.
Hot surface ignitor$100–$250
E27160-minute soft lockout: pressure switch open during ignition retries.
Outside, check that the furnace vent pipe is not blocked by snow, ice, leaves or a nest.
Draft inducer motor$400–$1,100
E27260-minute soft lockout: pressure switch kept opening while heating.
Outside, check that the furnace vent pipe is not blocked by snow, ice, leaves or a nest.
Draft inducer motor$400–$1,100
E27360-minute soft lockout: flame lost too many times while heating.
This needs a technician.
Flame sensor$80–$250
E27460-minute soft lockout: limit open over 3 minutes.
Replace a dirty air filter and open any closed supply or return vents.
High-limit switch$100–$375
E27560-minute soft lockout: flame out of sequence, now gone.
This needs a technician.
Gas valve$200–$800
E290Igniter circuit fault: failed igniter or triggering circuit.
This needs a technician.
Hot surface ignitor$100–$250
E292Indoor blower unable to start (variable speed).
This needs a technician.
Blower motor replacement (indoor)$500–$2,300
E150Refrigerant leak detected: thermostat lockout.
Have the indoor coil checked for a leak. This needs a technician.
Refrigerant leak repair$200–$1,500
E151Refrigerant leak sensor #1 fault (E152: sensor #2).
This needs a technician.
Visit $75–$200
E154Refrigerant leak sensor #1 communication lost (E155: sensor #2).
This needs a technician.
Visit $75–$200
E163Refrigerant leak detector control failure.
This needs a technician.
Furnace control board$300–$650
E000No error in memory.
Nothing to fix.
—
Source: Lennox — ML180UHVK Installation Instructions 508547-01 (12/2025)

Rheem furnace error codes

Also Ruud (same manufacturer). Codes change between control boards, so confirm yours against the chart printed inside the furnace door. Decode it step by step →

Green status + amber flame LEDs

Rheem and Ruud furnaces with a green STATUS LED and an amber FLAME LED on the control (documented for the (-)GPN/(-)GPP series). Count the green blinks for faults. The amber LED reports the flame signal.

CodeWhat it means · what to doMost likely part
Green 1 flashGreen, 1 blink: soft lockout.
Reset the system power and start over. If it repeats: flame sensor, igniter or gas valve.
Flame sensor$80–$250
Green 2 flashesGreen, 2 blinks: pressure switch circuit open.
Outside, check that the furnace vent pipe is not blocked by snow, ice, leaves or a nest.
Draft inducer motor$400–$1,100
Green 3 flashesGreen, 3 blinks: limit circuit open.
Replace a dirty air filter and open any closed supply or return vents.
High-limit switch$100–$375
Green 4 flashesGreen, 4 blinks: pressure switch circuit closed (when it should be open).
This needs a technician.
Visit $75–$200
Green 5 flashesGreen, 5 blinks: twinning fault (only on twinned furnaces).
This needs a technician.
Visit $75–$200
Amber slow blinkAmber slow blink: marginal flame sense.
A dirty flame sensor is a common cause.
Flame sensor$80–$250
Amber rapid blinkAmber rapid blink: unexpected flame.
This needs a technician.
Gas valve$200–$800
Amber steadyAmber steady: normal flame sense.
Nothing to fix.
—
Amber offAmber off: no flame present (normal between cycles).
Nothing to fix unless the furnace should be heating.
—
Source: Rheem — (-)GPN/(-)GPP Installation Instructions 92-24161-38-01 (troubleshooting chart)

What a furnace error code usually costs to fix

Most codes point to one of a handful of parts. A technician’s diagnostic visit costs $75–$200; tell them the code you read, it saves time.

PartRepair cost
Flame sensor$80–$250
Hot surface ignitor$100–$250
High-limit switch$100–$375
Draft inducer motor$400–$1,100
Gas valve$200–$800
Furnace control board$300–$650
Blower motor replacement (indoor)$500–$2,300
Transformer$100–$250
Installed national ranges, HomeGuide 2026.

Check a furnace repair quote →

Next toolTroubleshooter

Frequently asked questions

Why is my furnace blinking red?

The control board is reporting a fault. Count the flashes between pauses and look the number up for your brand: the most common causes are an overheating furnace (open limit, often a dirty filter), a vent or pressure switch problem, or failed ignition. On Trane furnaces a solid red light is also a fault.

What does it mean when my furnace blinks 3 times?

It depends on the brand. Goodman (single-LED boards): pressure switch stuck open. Trane: draft pressure error. Lennox (single-LED boards): pressure switch open while the inducer runs. Rheem (green LED): limit circuit open. Start by checking that the vent pipe outside is clear and the filter is clean.

Should I reset my furnace when the light is blinking?

Read the code first, then reset the power once. Carrier ignition and limit lockouts clear themselves after 3 hours and Lennox soft lockouts after 60 minutes. If the same code comes back, there is a fault to fix; a tripped rollout switch in particular needs a technician.

Is a steady light on the furnace board normal?

Usually yes. A steady LED means normal operation on Goodman and Lennox single-LED boards, and 24 V power on Carrier. The exception is Trane: a solid red LED there signals a gas valve error or low thermostat voltage.

Where is the error code chart on my furnace?

On a label inside the furnace door (often the blower door) or on the wiring diagram glued inside the cabinet. Carrier calls it the service label. If yours differs from this page, follow the label: it matches your control board.

How much does it cost to fix a furnace error code?

It depends on the part: flame sensor $80–$250, igniter $100–$250, limit switch $100–$375, inducer motor $400–$1,100, control board $300–$650. Many limit codes are fixed for the price of an air filter.

Best HVAC Repair GuideFurnace blinking red light? Decode the error code by brand
Updated
ScaleManufacturer documents · national price ranges

Estimates for planning only. Prices vary by region, home, and contractor. Gas, refrigerant, and high-voltage work must be done by a licensed technician.